LSI 3ware SAS 9750-8i Uživatelská příručka Strana 335

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 342
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 334
www.lsi.com/channel/products 323
Enclosure audio alarm activated but mute
(8047)
300
Enclosure audio alarm added (804A) 301
Enclosure audio alarm failed (8048) 300
Enclosure audio alarm removed (8049) 300
Enclosure audio alarm status unknown (804B) 301
Enclosure current normal (8044) 299
Enclosure current over (8045) 299
Enclosure current unknown (8046) 299
Enclosure fan added (8003) 290
Enclosure fan error (8001) 289
Enclosure fan normal (8000) 289
Enclosure fan off (8005) 291
Enclosure fan removed (8002) 290
Enclosure fan unknown (8004) 290
Enclosure power added (8033) 296
Enclosure power fail (8031) 295
Enclosure power normal (8030) 295
Enclosure power off (8037) 297
Enclosure power removed (8032) 296
Enclosure power unknown (8034) 296
Enclosure removed (0062) 286
Enclosure temp above operating (8024) 293
Enclosure temp added (8026) 294
Enclosure temp below operating (8023) 292
Enclosure temp critical (8027) 294
Enclosure temp high (8022) 292
Enclosure temp low (8021) 291
Enclosure temp normal (8020) 291
Enclosure temp removed (8025) 293
Enclosure temp unknown (8028) 294
Enclosure voltage normal (8040) 297
Enclosure voltage over (8041) 298
Enclosure voltage under (8042) 298
Enclosure voltage unknown (8043) 298
Flash file system error detected (003F) 275
Flash file system repaired (0040) 276
Incomplete unit detected (0006) 253
Initialize completed (0007) 254
Initialize failed (000E) 257
Initialize paused (003C) 274
Initialize started (000C) 257
Local link down (0065) 287
Local link up (0064) 287
Migration completed (0035) 271
Migration failed (0034) 270
Migration paused (003E) 275
Migration started (0033) 270
Primary DCB read error occurred (0042) 276
RAID key not found (0081) 289
Rebuild completed (0005) 253
Rebuild failed (0004) 252
Rebuild paused (003B) 273
Rebuild started (000B) 256
Replacement drive capacity too small (002E) 268
Reverted to emergency recovery firmware
(0066)
287
Sector repair completed (0023) 261
SO-DIMM not compatible (0037) 271
SO-DIMM not detected (0038) 272
Source drive ECC error overwritten(002C) 267
Source drive error occurred(002D) 267
Spare capacity too small for some units (0032) 269
Unclean shutdown detected (0008) 254
Unit inoperable (001E) 259
Unit number assignments lost (0041) 276
Unit Operational (001F) 260
Upgrade UDMA mode (0022) 261
Verify completed(002B) 266
Verify failed (002A) 265
Verify fixed data/parity mismatch (0036) 271
Verify not started, unit never initialized (002F) 268
Verify paused (003D) 274
Verify started (0029) 265
AEN messages 147, 228, 246
alarms 147
alert utility (WinAVAlarm) 148
viewing 147
Alarms page, 3DM 228
alert utility (WinAVAlarm) 148
All RAID keys failed validation (0080) 288
arrays 5
array roaming 5, 131, 133
definition 303
definition 303
moving from one controller to another 133
removing in 3DM 131
asterisk next to unit 204, 205
Auto Rebuild policy 17, 79
setting 82, 214
Auto Verify policy for units 213
setting (3DM) 115
auto-carving 83
auto-carving policy 79
auto-carving policy
setting
214
available drives, 3DM 225
B
background initialization after power failure
155
background tasks
background rebuild rate (definition) 303
background task mode 165, 212
background task mode, setting 168
background task rate 212
background task rate, setting 168
definition 16
initialization 152
overview 151
prioritizing 169
Zobrazit stránku 334