Error and Notification Messages
www.lsi.com/channel/products 279
Action
Replace the battery pack if none of the above causes apply and the warning
continues.
0048 Battery voltage is too high
Event Type
Error
Cause
The battery pack voltage being monitored by the Battery Backup Unit is too
high to backup the 3ware RAID controller.
Action
The battery pack must be replaced.
This may be a fault in the BBU control module. If you get this error, do the
following:
1 Turn off the computer and remove the 3ware RAID controller.
2 Remove the BBU control module from the 3ware RAID controller and
the battery module from the remote card.
3 Unplug the battery from the control module.
4 Return the BBU control module and battery module to 3ware.
For more details on removing the BBU, see the installation guide that came
with your 3ware RAID controller.
0049 Battery temperature is normal
Event Type
Information
Cause
The battery pack temperature being monitored by the Battery Backup Unit
fell outside of the acceptable range and then came back within the acceptable
range.
Action
None required
Zobrazit stránku 290
1 2 ... 286 287 288 289 290 291 292 293 294 295 296 ... 341 342

Komentáře k této Příručce

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema