282 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Cause
A battery test was started through CLI or 3DM 2.
Background Information
The test estimates how many hours the Battery Backup Unit will be able to
back up the 3ware RAID controller in case of a power failure.
This test performs a full battery charge/discharge/re-charge cycle and may
take up to 20 hours to complete. During this test the Battery Backup Unit
cannot backup the 3ware RAID controller. In addition, all units have their
write cache disabled until the test completes.
Action
None required.
See Also
See the Install Guide for your controller.
004F Cache synchronization skipped
Event Type
Warning
Cause
The cache synchronization that is normally performed when power is restored
after a power failure was skipped and write data is still being backed up in the
controller cache. This can occur if a unit was physically removed or became
inoperable during the power outage.
Action
Return missing drive(s) to the controller so that the missing write data can be
saved.
0050 Battery capacity test completed
Event Type
Information
Cause
The Battery Backup Unit has completed a battery capacity test.
Zobrazit stránku 293
1 2 ... 289 290 291 292 293 294 295 296 297 298 299 ... 341 342

Komentáře k této Příručce

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema