Troubleshooting
276 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
0040 Flash file system repaired
Event Type
Information
Cause
A corrupted flash file system has been successfully repaired.
Some of the flash files with insufficient data may have been lost in the
operation. The configuration parameters which are lost will then return to
their default values.
Action
We recommend using 3DM 2, 3BM, or CLI to check your settings, in case
they were not able to be restored.
0041 Unit number assignments lost
Event Type
Warning
Cause
The unit number assignments have been lost.
This may have occurred as a result of a soft reset.
Action
Please contact LSI 3ware technical support at
http://www.lsi.com/channel/ContactUs
0042 Primary DCB read error occurred
Event Type
Warning
Cause
The controller found an error while reading the primary copy of the Disk
Configuration Block (DCB).