Troubleshooting
252 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Cause
An error was encountered and the unit is now operating in degraded (non-
redundant) mode. This is usually due to a drive failure or the physical removal
of a drive from a redundant unit.
Action
Check hardware connections and reseat the drive or drives. Rescan the
controller from 3DM 2 or CLI to see if the unit has been restored. If you are
able to restore the unit before any data has been written to the unit, a rebuild
will not be necessary. If the unit remains degraded, replace the missing or
dead drives and initiate a rebuild.
See Also
“About Degraded Units” on page 144
“Rebuilding Units” on page 160
0003 Controller error occurred
Event Type
Error
Cause
The 3ware RAID controller has encountered an internal error.
Action
Please collect log files and contact LSI Customer Support, as a replacement
board may be required. Technical support is reachable at
http://www.lsi.com/channel/ContactUs. For information on collecting logs,
search the LSI Knowledge Base for keyword 12278 (use the Advanced
Search) at
https://selfservice.lsi.com/service/main.jsp
0004 Rebuild failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete a rebuild operation. This
error can be caused by drive errors on either the source or the destination of