3DM 2 Reference
222 3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.0
Maintenance Task Buttons for Existing Units
Below the list of units, a row of task buttons lets you perform maintenance
and configuration tasks related to the unit. Before clicking one of these
buttons, select the appropriate unit.
Verify Unit. Puts the selected unit in verifying mode. If the Advanced Verify
schedule is selected on the Scheduling page, the unit will not start actively
verifying until the scheduled time, and the status will indicate “Verify-
Paused.” (The Unit Details page will indicate whether a unit is actively
verifying.) If the Basic Verify schedule is active, clicking
Verify Unit begins
the verification process, and verify will begin within approximately 10 to 15
minutes.
If the unit you selected to verify is a redundant unit, the redundancy of the unit
will be verified. For example, it will check parity for a RAID 5 or check data
consistency for a RAID 1. If the unit you checked is not a redundant unit,
verify will do a surface scan of the media. During verification, I/O continues
normally. For RAID 0 and single disks, there is only a slight performance
loss. For redundant units, you can set the background task rate on the
Controller Settings page to specify whether more processing time should be
given to verifying or to I/O. For more information, see “About Verification”
on page 155 and “Setting Background Task Rate” on page 168.
While a unit is verifying, the status changes to Verifying and a
Stop Verify
link appears in the right-most column of the Unit Maintenance table.
Rebuild Unit. Replaces a failed drive in a degraded unit with an available
drive and begins rebuilding the RAID. When you select a degraded unit and
click
Rebuild Unit, a dialog box listing available drives appears, so that you
can select the drive you want to use. If the degraded unit has more than one
failed drive (for example, a RAID 10 where both mirrored pairs each have a
failed drive), you will repeat this process a second time.
If rebuild scheduling is enabled on the Scheduling page, the unit will not start
actively rebuilding until the scheduled time, and the status will change to say
“Rebuild-Paused.” (The Unit Details page indicates whether a unit is actively
Note: If the unit has not previously been initialized and you click Verify Unit, the
initialization process starts. Initialization cannot be halted, so no Stop Verify link
appears. (Initialization can be paused, however, through Scheduling. Initialization
follows the Rebuild/Migrate schedule, so turning on scheduling for Rebuild/Migrate
will pause initialization, as well.) For more information about initialization, see
“About Initialization” on page 152.
Zobrazit stránku 233
1 2 ... 229 230 231 232 233 234 235 236 237 238 239 ... 341 342

Komentáře k této Příručce

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema