RAID 50 units. This data can be used with the remaining user data to
recover the lost data if a disk drive fails.
PCB. Printed circuit board.
P-Chip. PCI interface chip that connects the PCI bus to the high-speed
internal bus and routes all data between the two using a packet switched
fabric. There is one P-chip per controller card.
Phy. Phys are transceivers that transmit and receive the serial data stream
that flows between the controller and the drives. 3ware 9750 controllers
have 8 phys. These phys are associated with virtual ports (vports) by
3ware software to establish up to 96 potential connections with the SAS
or SATA hard drives.
Phy Identifier. The ID number (0-7) assigned to each of the 8 phys on the
9750 controller.
Port. 3ware controller models prior to the 9690SA series have one or
many ports (typically 4, 8, 12, 16, or 24). Each port can be attached to a
single disk drive. On a controller with a Multi-lane™ serial port
connector, one connector supports four ports (eight if 24-port controller).
On 9750 and 9690SA series controllers, connections are made with phys
and vports (virtual ports). See “phy” and “VPort”.
Port ID. A unique identifier for a specific port in a system. Also called a
drive ID.
Queuing. SATA drives can use Native Command Queuing (NCQ) to
improve performance in applications that require a lot of random access
to data, such as server-type applications. When NCQ is enabled, the
commands are reordered on the drive itself.
NCQ must be supported by the drive. NCQ must be turned on in both the
drive and the RAID controller. By default, the RAID unit’s queue policy
is disabled when creating a unit.
RAID. Redundant array of inexpensive disks, combined into a unit
(array), to increase your storage system’s performance and provide fault
tolerance (protection against data loss).
Rapid RAID Recovery. The Rapid Raid Recovery feature increases the
speed with which a redundant unit can be made redundant again when a
rebuild is required. It can also increase the speed of verification or
initialization that may occur in the event of an unclean shutdown.
Read Cache. Read Cache stores data from media locally on the controller
to improve read access times for applications. The 3ware Read Cache
feature also includes an Intelligent Mode, which enables Intelligent Read
Prefetch (IRP). IRP includes a typical read-ahead caching method which
is used to proactively retrieve data from media and store it locally on the
controller with the anticipation that it may be requested by the host.
Zobrazit stránku 318
1 2 ... 314 315 316 317 318 319 320 321 322 323 324 ... 341 342

Komentáře k této Příručce

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema