Controller Settings page
www.lsi.com/channel/products 213
includes the Intelligent Read Prefetch (IRP) feature, which can improve
performance at higher queue depth in multiple read only or mixed read/write
stream environments. For additional information, see “Working with Read
Cache Settings” on page 111.
Auto Verify. Enabling Auto Verify ensures that a verify takes place following
either the Basic Auto Verify schedule or the Advanced Auto Verify schedule.
For details, see “Enabling or Disabling Auto Verify for a Unit” on page 115.
When Auto Verify is not enabled, verify tasks are only run if you manually
request one on the 3DM 2
Management page or in event of an unclean
shutdown.
Overwrite ECC (Continue on Source Error When Rebuilding). This policy
applies only to units which are redundant. (For units which are not redundant,
a check box is not available.) When this policy is set, ECC errors are ignored
when they are encountered during a rebuild. When this policy is not set, a
rebuild will abort upon encountering an ECC error and the unit will be set
back to Degraded.
Since this option could result in the loss of some source data in the event of
source errors, select this option only if you want to ensure that a rebuild will
complete successfully without manual intervention. If the rebuild fails and
Overwrite ECC is not selected, then you have the option to start a rebuild
manually. It is recommended that you execute a file system check when the
rebuild completes. Under Windows, you can do this by right-clicking on the
Drive and choosing Properties; then on the Tools tab, click Check Now. Under
Linux use the fsck utility command. For example,
fsck /dev/sda1.
Queuing. (Not applicable for SAS drives) This policy enables or disables
Native Command Queuing (NCQ) for SATA drives in the unit. By default,
queuing is disabled. You can enable it, if desired.
NCQ only operates when the feature is enabled at both the drive and the
controller. If a drive does not support NCQ, the policy setting for the
controller is ignored.
Enabling NCQ can improve performance in many applications; it causes
command reordering to be done on the drive itself.
StorSave Profile. The StorSave feature includes an option that lets you
change the StorSave Profile used for a unit. Three profiles are available:
Protection, Balanced, and Performance. These profiles automatically adjust
several different factors that affect protection and performance, including
whether FUA (Forced Unit Access) is honored, whether Write Journaling is
Note: The policy Overwrite ECC is equivalent to the “Continue on Source Error”
option in 3BM and the “IgnoreECC” option in the CLI.
Zobrazit stránku 224
1 2 ... 220 221 222 223 224 225 226 227 228 229 230 ... 341 342

Komentáře k této Příručce

Vikivzn 04 Jan 2024 | 17:05:44

urenrjrjkvnm

Evazoy 07 Jan 2024 | 01:42:43

Med

Renatimzn 07 Jan 2024 | 09:55:43

urenrjrjkvnm

Davidvmm 10 Jan 2024 | 11:36:21

coin

Davidefb 11 Jan 2024 | 11:24:30

coin

Viktorijsw 11 Jan 2024 | 19:38:33

Cinema