8-4 Troubleshooting
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
X Logical Drives
Degraded
x number of logical
drives signed on in a
degraded state.
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find if any physical
drives are not responding. Reconnect, replace,
or rebuild any drive that is not responding.
1 Logical Drive
Degraded
A logical drive signed on
in a degraded state.
Make sure all physical drives are properly
connected and are powered on.
Run MegaRAID Manager to find out if any
physical drives are not responding. Reconnect,
replace, or rebuild any drive that is not
responding.
Insufficient memory to
run BIOS. Press any key
to continue…
Not enough MegaRAID
memory to run
MegaRAID BIOS.
Make sure MegaRAID memory has been
properly installed.
Insufficient Memory Not enough memory on
the MegaRAID adapter
to support the current
configuration.
Make sure MegaRAID memory has been
properly installed.
The following SCSI IDs
are not responding:
Channel x:a.b.c
The physical drives with
SCSI IDs a, b, and c are
not responding on SCSI
channel x.
Make sure the physical drives are properly
connected and are powered on.
Table 8.2 BIOS Boot Error Messages (Cont.)
Message Problem Suggested Solution