Lsi 40909G-S Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Lsi 40909G-S. LSI 40909G-S User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 56
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
®
S14062
LSI40909G-S
PCI to Fibre Channel
Host Adapter for Sun
Solaris
USER’S
GUIDE
February 2001
Version 1.0
Zobrazit stránku 0
1 2 3 4 5 6 ... 55 56

Shrnutí obsahu

Strany 1 - Version 1.0

®S14062LSI40909G-SPCI to Fibre ChannelHost Adapter for SunSolarisUSER’SGUIDEFebruary 2001Version 1.0

Strany 2 - 408.433.8000

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pc1-2 LSI40909G-S DescriptionThe PCI interface includes these features:• Full 6

Strany 3

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcFeatures 1-31.2.4 FC Link Activity/Link Fault LEDThe LSI40909G-S provides a d

Strany 4

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pc1-4 LSI40909G-S Description

Strany 5 - Preface v

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris 2-13.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc12 pc12.938 pc13.851 pc48.583 pc52.5 pc34.5

Strany 6 - Revision Record

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pc2-2 Installing the LSI40909G-S2.2 Detailed Installation ProcedureThis section

Strany 7 - Contents

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcDetailed Installation Procedure 2-3the edge; do not touch board components or

Strany 8

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pc2-4 Installing the LSI40909G-SFigure 2.1 Hardware Connections for the LSI4090

Strany 9 - Description

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcDetailed Installation Procedure 2-5Figure 2.2 Inserting the Host AdapterStep

Strany 10 - 1.2.3 Board Characteristics

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pc2-6 Installing the LSI40909G-S

Strany 11 - Features 1-3

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris 3-1Chapter 3Software InstallationThis chapter describes the features and use of the LSI

Strany 12 - 1-4 LSI40909G-S Description

iiElectromagnetic Compatibility NoticesThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:1. Thi

Strany 13 - LSI40909G-S

3-2 Software Installation3.1.1 FeaturesThe following features of the LSI40909G-S minimize CPU utilization:• Uses state of the art Fusion-MPT interface

Strany 14 - 2.2.1 Before You Start

Installing the Sun SPARC Solaris Fusion-MPT™ Drivers 3-3Step 2. When the banner is displayed, press the Stop-A keys tointerrupt the boot process and s

Strany 15

3-4 Software Installation3.1.4 Identifying the FC DisksThe probe-scsi-all command is used to identify the FC disk deviceson your LSI Logic/IntraServer

Strany 16

Installing the Sun SPARC Solaris Fusion-MPT™ Drivers 3-5If the FC disks on your LSI Logic/IntraServer adapter are not identifiedby your system, check t

Strany 17

3-6 Software InstallationFigure 3.3 Persistent Device Mappingok show-disksa) /pci@1f,0/pci@1/IntraServer,fc@2/diskb) /pci@1f,0/pci@1/IntraServer,Ultra

Strany 18

Installing the itmpt Sun SPARC Solaris FC Driver 3-7To clear an entry in the persistent device map, use theclear-persistent command, as shown in Figur

Strany 19 - Software Installation

3-8 Software Installation3.2.1.1 Floppy Disk InstallIf you received the drivers on a floppy diskette, follow these steps:Step 1. Place the diskette in

Strany 20 - 3.1.2 System Requirements

Installing the itmpt Sun SPARC Solaris FC Driver 3-9Figure 3.5 pkgadd ProcedureThe following packages are available:1 TImpt LSI Logic/IntraServer Fusi

Strany 21

3-10 Software InstallationFigure 3.6 Completing Floppy Disk InstallationSee Figure 3.8 for additional information.Figure 3.7 Completing Floppy Disk In

Strany 22 - 3-4 Software Installation

Installing the itmpt Sun SPARC Solaris FC Driver 3-11Figure 3.8 /kernel/drv/ssd.confStep 4. The itmpt device driver is now installed. Reboot the machi

Strany 23

iiiThis document contains proprietary information of LSI Logic Corporation. Theinformation contained herein is not to be used by or disclosed to third

Strany 24 - 3-6 Software Installation

3-12 Software Installation3.2.2 Network Installation ProcedureIf you are using your LSI Logic/IntraServer adapter to support your SparcSolaris system

Strany 25 - 3.1.6 itmpt Device Driver

Installing the itmpt Sun SPARC Solaris FC Driver 3-13cd /floppy/floppy0Step 3. Execute the install.sh shell script to add the itmpt driver tothe boot

Strany 26 - 3-8 Software Installation

3-14 Software InstallationNote:You can obtain the platform_group from a machine of thesame type as the target client using theuname –mcommand.3.2.2.4

Strany 27

Troubleshooting 3-15Notes: The message “major number maximum based on server,not client” can safely be ignored.Your Sun machine will prompt you to all

Strany 28 - 3-10 Software Installation

3-16 Software Installationitmpt<n>: Could not allocatememory to read configuration data.The driver was unable to allocate memory required to proc

Strany 29

Troubleshooting 3-17itmpt<n>: The adapter ismalfunctioning or is of an unknowntype.The driver is not able to communicate with the hardware. Youm

Strany 30 - 3-12 Software Installation

3-18 Software Installation

Strany 31

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris 4-1Chapter 4LSI40909G-S TechnicalCharacteristicsThis chapter provides specific details ab

Strany 32 - 3-14 Software Installation

4-2 LSI40909G-S Technical CharacteristicsFigure 4.1 LSI40909G-S Components4.1.2 Electrical CharacteristicsUnder normal conditions, the LSI40909G-S max

Strany 33 - 3.3 Troubleshooting

Operational Environment 4-3The following parameters define the storage and transit environment forthe LSI40909G-S:• Storage Temperature: − 45 °Cto+85°C

Strany 35 - Troubleshooting 3-17

4-4 LSI40909G-S Technical Characteristics3.3 V voltage regulator. The PCI + 3 V/+ 5 V pins are usedto differentiate between a 5 V or a 3.3 V PCI signa

Strany 36 - 3-18 Software Installation

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris A-13.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc12 pc12.938 pc13.851 pc48.583 pc52.5 pc34.5

Strany 37 - Characteristics

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcA-2 Glossary of Terms and AbbreviationsConfiguration Refers to the way a compu

Strany 38 - SRAM SRAM

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcGlossary of Terms and Abbreviations A-3FC-1 Middle level of the FC-PH standar

Strany 39 - 4.2 Operational Environment

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcA-4 Glossary of Terms and AbbreviationsHost The computer system in which a SC

Strany 40 - 4.3 IEEE Unique Address

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcGlossary of Terms and Abbreviations A-5OperatingSystemA program that organize

Strany 41 - Abbreviations

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcA-6 Glossary of Terms and AbbreviationsResponder An FC term referring to the

Strany 42

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcGlossary of Terms and Abbreviations A-7System BIOS Controls the low level POS

Strany 43

3.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc48.583 pc52.5 pc34.5 pc44.25 pcA-8 Glossary of Terms and Abbreviations

Strany 44

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun SolarisCustomer FeedbackWe would appreciate your feedback on this document. Please copy thefollo

Strany 45

Preface vPrefaceThis book is the primary reference and user’s guide for the LSI LogicLSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris boa

Strany 46

Customer FeedbackReader’s CommentsFax your comments to: LSI Logic CorporationTechnical PublicationsM/S E-198Fax: 408.433.4333Please tell us how you ra

Strany 47

U.S. Distributorsby StateA. E. Avnet Electronicshttp://www.hh.avnet.comB. M. Bell Microproducts,Inc. (for HAB’s)http://www.bellmicro.comI. E. Insight

Strany 48

U.S. Distributorsby State(Continued)MontanaA. E. Tel: 800.526.1741W. E. Tel: 801.974.9953NebraskaA. E. Tel: 800.332.4375W. E. Tel: 303.457.9953NevadaL

Strany 49 - Customer Feedback

Direct SalesRepresentatives by State(Components and Boards)E. A. Earle AssociatesE. L. Electrodyne - UTGRP Group 2000I. S. Infinity Sales, Inc.ION ION

Strany 50 - LSI40909G-S PCI to Fibre

Sales Offices and DesignResource CentersLSI Logic CorporationCorporate Headquarters1551 McCarthy BlvdMilpitas CA 95035Tel: 408.433.8000Fax: 408.433.898

Strany 51 - U.S. Distributors

Sales Offices and DesignResource Centers(Continued)KoreaSeoulLSI Logic Corporation ofKorea Ltd10th Fl., Haesung 1 Bldg.942, Daechi-dong,Kangnam-ku, Seo

Strany 52 - (Continued)

International DistributorsAustraliaNew South WalesReptechnic Pty Ltd3/36 Bydown StreetNeutral Bay, NSW 2089♦Tel: 612.9953.9844Fax: 612.9953.9683Belgiu

Strany 53 - (Components and Boards)

vi PrefaceRelated PublicationsLSIFC909 Fibre Channel I/O Processor Technical Manual,Order Number S14029.ARevision RecordRevision Date Remarks1.0 02/01

Strany 54 - Resource Centers

Contents viiContentsChapter 1 LSI40909G-S Description1.1 General Description 1-11.2 Features 1-11.2.1 PCI Interface 1-11.2.2 FC Interface 1-21.2.3 Boa

Strany 55 - ♦Sales Offices with

viii ContentsChapter 4 LSI40909G-S Technical Characteristics4.1 Physical Environment 4-14.1.1 Physical Characteristics 4-14.1.2 Electrical Characteris

Strany 56 - ♦Tel: 91.80.664.5530

LSI40909G-S PCI to Fibre Channel Host Adapter for Sun Solaris 1-13.75 pc 10.25 pc 11.25 pc 38.25 pc4.333 pc12 pc12.938 pc13.851 pc48.583 pc52.5 pc34.5

Komentáře k této Příručce

Žádné komentáře